Raw data for "Cross-laboratory evaluation of multiplex bead assays including independent common reference standards for immunological monitoring of observational and interventional human studies"

van Meijgaarden, KE, Khatri, B, Smith, SG, Drittij, Anne M. F. H., de Paus, RA, Goeman, JJ, Ho, MM, Dockrell, HMORCID logo, McShane, H, Joosten, SA and Ottenhoff, THM (2018). Raw data for "Cross-laboratory evaluation of multiplex bead assays including independent common reference standards for immunological monitoring of observational and interventional human studies". [Dataset]. PLOS One. https://doi.org/10.1371/journal.pone.0201205.s004
Copy

Multiplex assays are increasingly applied to analyze multicomponent signatures of human immune responses, including the dynamics of cytokine and chemokine production, in observational as well as interventional studies following treatment or vaccination. However, relatively limited information is available on the performance of the different available multiplex kits, and comparative evaluations addressing this important issue are lacking. To fill this knowledge gap we performed a technical comparison of multiplex bead assays from 4 manufacturers, each represented by 3 different lots, and with the assays performed by 3 different laboratories. To cross compare kits directly, spiked samples, biological samples and a newly made reference standard were included in all assays. Analyses were performed on 324 standard curves to allow for evaluation of the quality of the standard curves and the subsequent interpretation of biological specimens. Manufacturer was the factor which contributed most to the observed variation whereas variation in lots, laboratory or type of detection reagent contributed minimally. Inclusion of a common reference standard allowed us to overcome observed differences in cytokine and chemokine levels between manufacturers. We strongly recommend using multiplex assays from the same manufacturer within a single study and across studies that are likely to compare results in a quantitative manner. Incorporation of common reference standards, and application of the same analysis method in assays can overcome many analytical biases and thus could bridge comparison of independent immune profiling (e.g. vaccine immunogenicity) studies. With these recommendations taken into account, the multiplex bead assays performed as described here are useful tools in capturing complex human immune-signatures in observational and interventional studies.

Keywords

Cytokines, Chemokines, Curve fitting, Distribution curves,, Immune response, Vaccination and immunization, Netherlands, Vaccines

No files available. Please consult associated links.


Atom BibTeX OpenURL ContextObject in Span Multiline CSV OpenURL ContextObject Dublin Core (with Type as Type) MPEG-21 DIDL Data Cite XML EndNote HTML Citation JSON METS MODS RDF+N3 RDF+N-Triples RDF+XML Reference Manager Refer Simple Metadata ASCII Citation EP3 XML
Export

Downloads