10.17037/DATA.00004763
Data collected from 2,097 adolescents aged 10-19 years who gave informed consent, or informed assent with parental/guardian consent, to participate in a prospective intervention study to assess the feasibility and short-term impact of an adolescent health check-up programme in selected schools and community venues in Chitungwiza, Zimbabwe between October 2022 to September 2023.
This codebook describes the 230 variables contained in the HearX dataset, which was produced as part of the Y-Check Zimbabwe intervention 2022-23. The codebook was created in reference to the HearX hear test data dictionary (version 01 March 2024). The headset model used to conduct the audiometric assessment was Sennheiser HD 280.
| Variable Name | Variable Label | Answer Label | Answer Code | Variable Type |
| TestDate | Date of testing (DD/MM/YYYY HH:mm) | Date | ||
| Facility | Facility name | String | ||
| Community 1 | Community 1 | |||
| Community 2 | Community 2 | |||
| School A | School A | |||
| School B | School B | |||
| School D | School D | |||
| School E | School E | |||
| School F | School F | |||
| pid | Reference number | String | ||
| Duration | The duration of the audiometric assessment | Numeric | ||
| Result | Result of the overall test | String | ||
| Pass | Pass | |||
| Referred | Referred | |||
| _125_left_test_1_intensity | In any protocol for audiometry there is a conditioning tone. Our conditioning tone is a 1000 Hz at 35 dB. Both these tones will be presented in each respective ear before testing starts. Once the protocol starts and there is a significant difference between the conditioning tone's response and the response in the protocol, it will be flagged as a threshold concern | String | ||
| _125_left_test_1_result | Left: left ear | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _125_left_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Left: left ear. 125 Hertz (Hz) | Numeric | ||
| _250_left_test_1_intensity | as per variable _125_left_test_1_intensity | Numeric | ||
| _250_left_test_1_result | Audiometric assessment test result for their left ear at 250 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _250_left_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Left: left ear. 250 Hertz (Hz) | Numeric | ||
| _500_left_test_1_intensity | as per variable _125_left_test_1_intensity | Numeric | ||
| _500_left_test_1_result | Audiometric assessment test result for their left ear at 500 Hertz (Hz) | Numeric | ||
| _500_left_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Left: left ear. 500 Hertz (Hz) | Numeric | ||
| _750_left_test_1_intensity | as per variable _125_left_test_1_intensity | Numeric | ||
| _750_left_test_1_result | Audiometric assessment test result for their left ear at 750 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _750_left_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Left: left ear. 750 Hertz (Hz) | Numeric | ||
| _1000_left_test_1_intensity | as per variable _125_left_test_1_intensity | Numeric | ||
| _1000_left_test_1_result | Audiometric assessment test result for their left ear at 1000 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _1000_left_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Left: left ear. 1000 Hertz (Hz) | Numeric | ||
| _1500_left_test_1_intensity | as per variable _125_left_test_1_intensity | Numeric | ||
| _1500_left_test_1_result | Audiometric assessment test result for their left ear at 1500 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _1500_left_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Left: left ear. 1500 Hertz (Hz) | Numeric | ||
| _2000_left_test_1_intensity | as per variable _125_left_test_1_intensity | Numeric | ||
| _2000_left_test_1_result | Audiometric assessment test result for their left ear at 2000 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _2000_left_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Left: left ear. 2000 Hertz (Hz) | Numeric | ||
| _3000_left_test_1_intensity | as per variable _125_left_test_1_intensity | Numeric | ||
| _3000_left_test_1_result | Audiometric assessment test result for their left ear at 3000 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _3000_left_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Left: left ear. 3000 Hertz (Hz) | Numeric | ||
| _4000_left_test_1_intensity | as per variable _125_left_test_1_intensity | Numeric | ||
| _4000_left_test_1_result | Audiometric assessment test result for their left ear at 4000 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _4000_left_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Left: left ear. 4000 Hertz (Hz) | Numeric | ||
| _6000_left_test_1_intensity | as per variable _125_left_test_1_intensity | Numeric | ||
| _6000_left_test_1_result | Audiometric assessment test result for their left ear at 6000 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _6000_left_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Left: left ear. 6000 Hertz (Hz) | Numeric | ||
| _8000_left_test_1_intensity | as per variable _125_left_test_1_intensity | Numeric | ||
| _8000_left_test_1_result | Audiometric assessment test result for their left ear at 8000 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _8000_left_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for C28, the specific frequency while the test is being conducted. Left: left ear. 8000 Hertz (Hz) | Numeric | ||
| _10000_left_test_1_intensity | as per variable _125_left_test_1_intensity | Numeric | ||
| _10000_left_test_1_result | Audiometric assessment test result for their left ear at 10000 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _10000_left_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Left: left ear. 10000 Hertz (Hz) | Numeric | ||
| _12500_left_test_1_intensity | as per variable _125_left_test_1_intensity | Numeric | ||
| _12500_left_test_1_result | Audiometric assessment test result for their left ear at 12500 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _12500_left_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Left: left ear. 12500 Hertz (Hz) | Numeric | ||
| _16000_left_test_1_intensity | as per variable _125_left_test_1_intensity | Numeric | ||
| _16000_left_test_1_result | Audiometric assessment test result for their left ear at 16000 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _16000_left_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Left: left ear. 16000 Hertz (Hz) | Numeric | ||
| _125_right_test_1_intensity |
In any protocol for audiometry there is a conditioning tone. Our conditioning tone is a 1000 Hz at 35 dB. Both these tones will be presented in each respective ear before testing starts. Once the protocol starts and there is a significant difference between the conditioning tone's response and the response in the protocol, it will be flagged as a threshold concern Right: right ear |
Numeric | ||
| _125_right_test_1_result | Audiometric assessment test result for their right ear at 125 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _125_right_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Right: right ear. 125 Hertz (Hz) | Numeric | ||
| _250_right_test_1_intensity | as per variable _125_right_test_1_intensity | Numeric | ||
| _250_right_test_1_result | Audiometric assessment test result for their right ear at 250 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _250_right_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Right: right ear. 250 Hertz (Hz) | Numeric | ||
| _500_right_test_1_intensity | as per variable _125_right_test_1_intensity | Numeric | ||
| _500_right_test_1_result | Audiometric assessment test result for their right ear at 500 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _500_right_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Right: right ear. 500 Hertz (Hz) | Numeric | ||
| _750_right_test_1_intensity | as per variable _125_right_test_1_intensity | Numeric | ||
| _750_right_test_1_result | Audiometric assessment test result for their right ear at 750 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _750_right_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Right: right ear. 750 Hertz (Hz) | Numeric | ||
| _1000_right_test_1_intensity | as per variable _125_right_test_1_intensity | Numeric | ||
| _1000_right_test_1_result | Audiometric assessment test result for their right ear at 1000 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _1000_right_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Right: right ear. 1000 Hertz (Hz) | Numeric | ||
| _1500_right_test_1_intensity | as per variable _125_right_test_1_intensity | Numeric | ||
| _1500_right_test_1_result | Audiometric assessment test result for their right ear at 15000 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _1500_right_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Right: right ear. 1500 Hertz (Hz) | Numeric | ||
| _2000_right_test_1_intensity | as per variable _125_right_test_1_intensity | Numeric | ||
| _2000_right_test_1_result | Audiometric assessment test result for their right ear at 2000 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _2000_right_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Right: right ear. 2000 Hertz (Hz) | Numeric | ||
| _3000_right_test_1_intensity | as per variable _125_right_test_1_intensity | Numeric | ||
| _3000_right_test_1_result | Audiometric assessment test result for their right ear at Hertz 3000 (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _3000_right_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Right: right ear. 3000 Hertz (Hz) | Numeric | ||
| _4000_right_test_1_intensity | as per variable _125_right_test_1_intensity | Numeric | ||
| _4000_right_test_1_result | Audiometric assessment test result for their right ear at 40000 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _4000_right_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Right: right ear. 4000 Hertz (Hz) | Numeric | ||
| _6000_right_test_1_intensity | as per variable _125_right_test_1_intensity | Numeric | ||
| _6000_right_test_1_result | Audiometric assessment test result for their right ear at 6000 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _6000_right_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Right: right ear. 6000 Hertz (Hz) | Numeric | ||
| _8000_right_test_1_intensity | as per variable _125_right_test_1_intensity | Numeric | ||
| _8000_right_test_1_result | Audiometric assessment test result for their right ear at 8000 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _8000_right_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Right: right ear. 8000 Hertz (Hz) | Numeric | ||
| _10000_right_test_1_intensity | as per variable _125_right_test_1_intensity | Numeric | ||
| _10000_right_test_1_result | Audiometric assessment test result for their right ear at 10000 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _10000_right_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Right: right ear. 10000 Hertz (Hz) | Numeric | ||
| _12500_right_test_1_intensity | as per variable _125_right_test_1_intensity | Numeric | ||
| _12500_right_test_1_result | Audiometric assessment test result for their right ear at 12500 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _12500_right_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Right: right ear. 12500 Hertz (Hz) | Numeric | ||
| _16000_right_test_1_intensity | as per variable _125_right_test_1_intensity | Numeric | ||
| _16000_right_test_1_result | Audiometric assessment test result for their right ear at 16000 Hertz (Hz) | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _16000_right_test_1_noise | The intensity of the ambient noise less the maximum ambient noise permissible (MPANL) for the specific frequency while the test is being conducted. Right: right ear. 16000 Hertz (Hz) | Numeric | ||
| _125_left_test_2_intensity | Second round of testing - same as PER _125_left_test_1_intensity | Numeric | ||
| _125_left_test_2_result | Second round of testing - same as PER _125_left_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _125_left_test_2_noise | Second round of testing - same as PER _125_left_test_1_noise | Numeric | ||
| _125_left_test_2_severity | Second round of testing - same as PER _125_left_test_1_severity | Numeric | ||
| _125_left_test_2_severity_thresh | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Left: left ear. 125 Hertz (Hz) | Numeric | ||
| _250_left_test_2_intensity | Second round of testing - same as PER _250_left_test_1_intensity | Numeric | ||
| _250_left_test_2_result | Second round of testing - same as PER _250_left_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _250_left_test_2_noise | Second round of testing - same as PER _250_left_test_1_noise | Numeric | ||
| _250_left_test_2_severity | Second round of testing - same as PER _250_left_test_1_severity | Numeric | ||
| _250_left_test_2_severity_thresh | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trial. Left: left ear. 250 Hertz (Hz) | Numeric | ||
| _500_left_test_2_intensity | Second round of testing - same as PER _500_left_test_1_intensity | Numeric | ||
| _500_left_test_2_result | Second round of testing - same as PER _500_left_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _500_left_test_2_noise | Second round of testing - same as PER _500_left_test_1_noise | Numeric | ||
| _500_left_test_2_severity | Second round of testing - same as PER _500_left_test_1_severity | Numeric | ||
| _500_left_test_2_severity_thresh | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Left: left ear. 500 Hertz (Hz) | Numeric | ||
| _750_left_test_2_intensity | Second round of testing - same as PER _750_left_test_1_intensity | Numeric | ||
| _750_left_test_2_result | Second round of testing - same as PER _750_left_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _750_left_test_2_noise | Second round of testing - same as PER _750_left_test_1_noise | Numeric | ||
| _750_left_test_2_severity | Second round of testing - same as PER _750_left_test_1_severity | Numeric | ||
| _750_left_test_2_severity_thresh | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Left: left ear. 750 Hertz (Hz) | Numeric | ||
| _1000_left_test_2_intensity | Second round of testing - same as PER _1000_left_test_1_intensity | Numeric | ||
| _1000_left_test_2_result | Second round of testing - same as PER _1000_left_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _1000_left_test_2_noise | Second round of testing - same as PER _1000_left_test_1_noise | Numeric | ||
| _1000_left_test_2_severity | Second round of testing - same as PER _1000_left_test_1_severity | Numeric | ||
| _1000_left_test_2_severity_thres | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Left: left ear. 1000 Hertz (Hz) | Numeric | ||
| _1500_left_test_2_intensity | Second round of testing - same as PER _1500_left_test_1_intensity | Numeric | ||
| _1500_left_test_2_result | Second round of testing - same as PER _1500_left_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _1500_left_test_2_noise | Second round of testing - same as PER _1500_left_test_1_noise | Numeric | ||
| _1500_left_test_2_severity | Second round of testing - same as PER _1500_left_test_1_severity | Numeric | ||
| _1500_left_test_2_severity_thres | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Left: left ear. 1500 Hertz (Hz) | Numeric | ||
| _2000_left_test_2_intensity | Second round of testing - same as PER _2000_left_test_1_intensity | Numeric | ||
| _2000_left_test_2_result | Second round of testing - same as PER _2000_left_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _2000_left_test_2_noise | Second round of testing - same as PER _2000_left_test_1_noise | Numeric | ||
| _2000_left_test_2_severity | Second round of testing - same as PER _2000_left_test_1_severity | Numeric | ||
| _2000_left_test_2_severity_thres | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Left: left ear. 2000 Hertz (Hz) | Numeric | ||
| _3000_left_test_2_intensity | Second round of testing - same as PER _3000_left_test_1_intensity | Numeric | ||
| _3000_left_test_2_result | Second round of testing - same as PER _3000_left_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _3000_left_test_2_noise | Second round of testing - same as PER _3000_left_test_1_noise | Numeric | ||
| _3000_left_test_2_severity | Second round of testing - same as PER _3000_left_test_1_severity | Numeric | ||
| _3000_left_test_2_severity_thres | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Left: left ear. 3000 Hertz (Hz) | Numeric | ||
| _4000_left_test_2_intensity | Second round of testing - same as PER _4000_left_test_1_intensity | Numeric | ||
| _4000_left_test_2_result | Second round of testing - same as PER _4000_left_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _4000_left_test_2_noise | Second round of testing - same as PER _4000_left_test_1_noise | Numeric | ||
| _4000_left_test_2_severity | Second round of testing - same as PER _4000_left_test_1_severity | Numeric | ||
| _4000_left_test_2_severity_thres | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Left: left ear. 4000 Hertz (Hz) | Numeric | ||
| _6000_left_test_2_intensity | Second round of testing - same as PER _6000_left_test_1_intensity | Numeric | ||
| _6000_left_test_2_result | Second round of testing - same as PER _6000_left_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _6000_left_test_2_noise | Second round of testing - same as PER _6000_left_test_1_noise | Numeric | ||
| _6000_left_test_2_severity | Second round of testing - same as PER _6000_left_test_1_severity | Numeric | ||
| _6000_left_test_2_severity_thres | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Left: left ear. 6000 Hertz (Hz) | Numeric | ||
| _8000_left_test_2_intensity | Second round of testing - same as PER _8000_left_test_1_intensity | Numeric | ||
| _8000_left_test_2_result | Second round of testing - same as PER _8000_left_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _8000_left_test_2_noise | Second round of testing - same as PER _8000_left_test_1_noise | Numeric | ||
| _8000_left_test_2_severity | Second round of testing - same as PER _8000_left_test_1_severity | Numeric | ||
| _8000_left_test_2_severity_thres | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Left: left ear. 8000 Hertz (Hz) | Numeric | ||
| _10000_left_test_2_intensity | Second round of testing - same as PER _10000_left_test_1_intensity | Numeric | ||
| _10000_left_test_2_result | Second round of testing - same as PER _10000_left_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _10000_left_test_2_noise | Second round of testing - same as PER _10000_left_test_1_noise | Numeric | ||
| _10000_left_test_2_severity | Second round of testing - same as PER _10000_left_test_1_severity | Numeric | ||
| _10000_left_test_2_severity_thre | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Left: left ear. 10000 Hertz (Hz) | Numeric | ||
| _12500_left_test_2_intensity | Second round of testing - same as PER _12500_left_test_1_intensity | Numeric | ||
| _12500_left_test_2_result | Second round of testing - same as PER _12500_left_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _12500_left_test_2_noise | Second round of testing - same as PER _12500_left_test_1_noise | Numeric | ||
| _12500_left_test_2_severity | Second round of testing - same as PER _12500_left_test_1_severity | Numeric | ||
| _12500_left_test_2_severity_thre | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Left: left ear. 12500 Hertz (Hz) | Numeric | ||
| _16000_left_test_2_intensity | Second round of testing - same as PER _16000_left_test_1_intensity | Numeric | ||
| _16000_left_test_2_result | Second round of testing - same as PER _16000_left_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _16000_left_test_2_noise | Second round of testing - same as PER _16000_left_test_1_noise | Numeric | ||
| _16000_left_test_2_severity | Second round of testing - same as PER _16000_left_test_1_severity | Numeric | ||
| _16000_left_test_2_severity_thre | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Left: left ear. 16000 Hertz (Hz) | Numeric | ||
| _125_right_test_2_intensity | Second round of testing - same as PER _125_right_test_1_intensity | Numeric | ||
| _125_right_test_2_result | Second round of testing - same as PER _125_right_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _125_right_test_2_noise | Second round of testing - same as PER _125_right_test_1_noise | Numeric | ||
| _125_right_test_2_severity | Second round of testing - same as PER _125_right_test_1_severity | Numeric | ||
| _125_right_test_2_severity_thres | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Right: right ear. 125 Hertz (Hz) | Numeric | ||
| _250_right_test_2_intensity | Second round of testing - same as PER _250_right_test_1_intensity | Numeric | ||
| _250_right_test_2_result | Second round of testing - same as PER _250_right_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _250_right_test_2_noise | Second round of testing - same as PER _250_right_test_1_noise | Numeric | ||
| _250_right_test_2_severity | Second round of testing - same as PER _250_right_test_1_severity | Numeric | ||
| _250_right_test_2_severity_thres | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Right: right ear. 250 Hertz (Hz) | Numeric | ||
| _500_right_test_2_intensity | Second round of testing - same as PER _500_right_test_1_intensity | Numeric | ||
| _500_right_test_2_result | Second round of testing - same as PER _500_right_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _500_right_test_2_noise | Second round of testing - same as PER _500_right_test_1_noise | Numeric | ||
| _500_right_test_2_severity | Second round of testing - same as PER _500_right_test_1_severity | Numeric | ||
| _500_right_test_2_severity_thres | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Right: right ear. 500 Hertz (Hz) | Numeric | ||
| _750_right_test_2_intensity | Second round of testing - same as PER _750_right_test_1_intensity | Numeric | ||
| _750_right_test_2_result | Second round of testing - same as PER _750_right_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _750_right_test_2_noise | Second round of testing - same as PER _750_right_test_1_noise | Numeric | ||
| _750_right_test_2_severity | Second round of testing - same as PER _750_right_test_1_severity | Numeric | ||
| _750_right_test_2_severity_thres | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Right: right ear. 750 Hertz (Hz) | Numeric | ||
| _1000_right_test_2_intensity | Second round of testing - same as PER _1000_right_test_1_intensity | Numeric | ||
| _1000_right_test_2_result | Second round of testing - same as PER _1000_right_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _1000_right_test_2_noise | Second round of testing - same as PER _1000_right_test_1_noise | Numeric | ||
| _1000_right_test_2_severity | Second round of testing - same as PER _1000_right_test_1_severity | Numeric | ||
| _1000_right_test_2_severity_thre | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Right: right ear. 1000 Hertz (Hz) | Numeric | ||
| _1500_right_test_2_intensity | Second round of testing - same as PER _1500_right_test_1_intensity | Numeric | ||
| _1500_right_test_2_result | Second round of testing - same as PER _1500_right_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _1500_right_test_2_noise | Second round of testing - same as PER _1500_right_test_1_noise | Numeric | ||
| _1500_right_test_2_severity | Second round of testing - same as PER _1500_right_test_1_severity | Numeric | ||
| _1500_right_test_2_severity_thre | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Right: right ear. 1500 Hertz (Hz) | Numeric | ||
| _2000_right_test_2_intensity | Second round of testing - same as PER _2000_right_test_1_intensity | Numeric | ||
| _2000_right_test_2_result | Second round of testing - same as PER _2000_right_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _2000_right_test_2_noise | Second round of testing - same as PER _2000_right_test_1_noise | Numeric | ||
| _2000_right_test_2_severity | Second round of testing - same as PER _2000_right_test_1_severity | Numeric | ||
| _2000_right_test_2_severity_thre | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Right: right ear. 2000 Hertz (Hz) | Numeric | ||
| _3000_right_test_2_intensity | Second round of testing - same as PER _3000_right_test_1_intensity | Numeric | ||
| _3000_right_test_2_result | Second round of testing - same as PER _3000_right_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _3000_right_test_2_noise | Second round of testing - same as PER _3000_right_test_1_noise | Numeric | ||
| _3000_right_test_2_severity | Second round of testing - same as PER _3000_right_test_1_severity | Numeric | ||
| _3000_right_test_2_severity_thre | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Right: right ear. 3000 Hertz (Hz) | Numeric | ||
| _4000_right_test_2_intensity | Second round of testing - same as PER _4000_right_test_1_intensity | Numeric | ||
| _4000_right_test_2_result | Second round of testing - same as PER _4000_right_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _4000_right_test_2_noise | Second round of testing - same as PER _4000_right_test_1_noise | Numeric | ||
| _4000_right_test_2_severity | Second round of testing - same as PER _4000_right_test_1_severity | Numeric | ||
| _4000_right_test_2_severity_thre | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Right: right ear. 4000 Hertz (Hz) | Numeric | ||
| _6000_right_test_2_intensity | Second round of testing - same as PER _6000_right_test_1_intensity | Numeric | ||
| _6000_right_test_2_result | Second round of testing - same as PER _6000_right_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _6000_right_test_2_noise | Second round of testing - same as PER _6000_right_test_1_noise | Numeric | ||
| _6000_right_test_2_severity | Second round of testing - same as PER _6000_right_test_1_severity | Numeric | ||
| _6000_right_test_2_severity_thre | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Right: right ear. 6000 Hertz (Hz) | Numeric | ||
| _8000_right_test_2_intensity | Second round of testing - same as PER _8000_right_test_1_intensity | Numeric | ||
| _8000_right_test_2_result | Second round of testing - same as PER _8000_right_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _8000_right_test_2_noise | Second round of testing - same as PER _8000_right_test_1_noise | Numeric | ||
| _8000_right_test_2_severity | Second round of testing - same as PER _8000_right_test_1_severity | Numeric | ||
| _8000_right_test_2_severity_thre | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Right: right ear. 8000 Hertz (Hz) | Numeric | ||
| _10000_right_test_2_intensity | Second round of testing - same as PER _10000_right_test_1_intensity | Numeric | ||
| _10000_right_test_2_result | Second round of testing - same as PER _10000_right_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _10000_right_test_2_noise | Second round of testing - same as PER _10000_right_test_1_noise | Numeric | ||
| _10000_right_test_2_severity | Second round of testing - same as PER _10000_right_test_1_severity | Numeric | ||
| _10000_right_test_2_severity_thr | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Right: right ear. 10000 Hertz (Hz) | Numeric | ||
| _12500_right_test_2_intensity | Second round of testing - same as PER _12500_right_test_1_intensity | Numeric | ||
| _12500_right_test_2_result | Second round of testing - same as PER _12500_right_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _12500_right_test_2_noise | Second round of testing - same as PER _12500_right_test_1_noise | Numeric | ||
| _12500_right_test_2_severity | Second round of testing - same as PER _12500_right_test_1_severity | Numeric | ||
| _12500_right_test_2_severity_thr | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Right: right ear. 12500 Hertz (Hz) | Numeric | ||
| _16000_right_test_2_intensity | Second round of testing - same as PER _16000_right_test_1_intensity | Numeric | ||
| _16000_right_test_2_result | Second round of testing - same as PER _16000_right_test_1_result | String | ||
| Pass | Pass | |||
| Fail | Fail | |||
| _16000_right_test_2_noise | Second round of testing - same as PER _16000_right_test_1_noise | Numeric | ||
| _16000_right_test_2_severity | Second round of testing - same as PER _16000_right_test_1_severity | Numeric | ||
| _16000_right_test_2_severity_thr | Threshold: the level at which a test subject responds to a test signal (tone) 50% of the time on ascending trials. Right: right ear. 16000 Hertz (Hz) | Numeric | ||
| date_only | Date of testing (day/month/year) | DD-MM-YYYY | Date |